How to safeguard Air Compressor from Excessive Vibrations.

In my last post,I wrote about minimum safty switches required to be install on Air Compressor,that are LOPS,LCWPS,HDATS & Motor Overload Relay.It is also important to protect your compressor from excessive vibrations developed due to operation or any other reasons.Unfortunately many plants are not using this safty switch on their compressor.If you are using or interested to install Excessive Vibration switch,this post will help you to increase your knowledge.many different Vibration Switches are available in market but in old days a very accurate switch"Robertshaws" made in USA make VIBRASWITCH is adopted by
various plants.The details is as below.
The switch is to protect the crankcase/crankshaft against any damage from malfunctions that can be detected as an increase in vibration.This is mounted on
crankcase of compressor.It is sensitive to vibration in the direction perpendicular to its mounting base.
It contains a vibration detecting mechanism,which also function as a "Mechanical Amplifire" to activate a snap-action switch when the selected level of
vibration is exceeded and the detecting mechanism "Trips".
The mechanism may be reset manually,by depressing the reset button to make the armature away from latching magnet until it is held against the stop pin.
Adjustment of operating set point.
The operating set point for the"Vibraswitch" varies with the type of Air Compressor & its location on the machine.The set point adjustment suggested here are for machine which are working in good or normal condition.
The switch is adjusted by three step procedure,for making the adjustment, cover must be removed to gain access to the set point adjustment screw.
01)Zero Vibration Level Measurement:-
When the compressor on which the Vibraswitch is mounted,not operating,back-off the set point adjustment screw counter clockwise two turns & press the reset button.Then turn the set point adjustment screw slowly clockwise until actuation occurs.This is the zero vibration point or actuating point,when the compressor not in running condition.A mark should made to permanently record this "Zero Vibration point".Subsequent measurments are made relative to this point.
02)Normal G-Level measurement:-
When the compressor is in operating condition,back off the set point adjustment screw one turn counter clockwise and reset.If it will not reset,back-off slowly
until reset.Again turn the set point adjustment screw slowly clockwise until actuation occurs,mark the position.The difference between the two actuating points
in step 01 & step 02 is the normal G-level of the Air Compressor,in scale divisions.One scale division is 0.1g & one full revolution is 1.0g
03)Fine Set Point Adjustment:-
Rotate the set point adjustment screw one full turn counter clockwise from the point where actuation occured in above step 02.
NOTE:-Use Ohm meter to observe the actuation of the Vibraswitch visually in noisy surroundings.
prasanna
http://www.pnengineering.blogspot.com/
Vote Result










Score: 0.0, Votes: 0
- prasannas's blog
- Add new comment
- 60 reads
Similar entries
- Safety switches used in Air Compressor.
- High Discharge Air Temperature Switch used for safty of Air Compressor.
- Avoid Breakdown of Air Compressor due to Low Water Flow.
- 15 Useful Tips to obtain best result from Electric Screw Air Compressor.
- How Electro-magnetic Overload Relay works?
- How Electric Screw Air Compressor Works?
- The important fault indication device used in Air Compressor.

Technorati Tags:
Recent comments
17 hours 30 min ago
18 hours 9 min ago
18 hours 10 min ago
1 day 9 hours ago
1 day 10 hours ago
1 day 11 hours ago
3 days 22 hours ago
3 days 22 hours ago
4 days 14 hours ago
4 days 19 hours ago